ED500 Maxi Revolving Door – Break-Out System 2017-05-18T09:56:48+00:00

« ED500 – Maxi Revolving Door

MANUAL AND MAGNETIC BREAK-OUT SYSTEM

Magnetic Break-Out System

The wings are permanently locked in automatic mode. In case panic and folds of wings are desired, folding of wings is provided by pressing emergency stop button.

Manual Break-Out System

The wings are folded by applying 220 N force manually to the wings.

  • In panic situations such as fire and earthquake,
  • Where the ventilation of the place is desired,
  • In case of cancellation of  use of the revolving door it to creates an entrance and exit corridor.
  • The corridor is created by manually pushing or pulling the wings

* If there is no panic bar door on the side of the revolving door it is recommended to use folding wing.

3 Wing – Stationary Position

4 Wing – Stationary Position